Fire alarm systems

  • FPC-500 Conventional Fire Panel
  • LCD with backlight screen and status indication for all detector zones
  • Self-explanatory icons for intuitive operation
  • Two history functions with 1,000 entries each, one for events and the other for walk tests
  • Fully certified according to EN 54, featuring outstanding quality and reliability from Bosch
  • Autoscroll function for easy checking of the overall panel configuration
  • FCP 320/FCH 320 Conventional Automatic Fire Detectors
  • Evaluation electronics for highly reliable detection
  • Automatic threshold adjustment (drift compensation) for pollution soiling of the optical sensor
  • Mechanical lock to prevent removal/theft (can be activated and deactivated)
  • Dust-proof labyrinth and cap design
  • All detectors have a “chamber-maid plug” at the bottom for cleaning the optical chamber with compressed air (not required for the FCH-T320 heat detector)
  • FCP 500 Conventional Automatic Fire Detectors
  • Modern, ultra-flat design that blends into the decor
  • Range of color rings for nearly invisible installation
  • Smooth, easy-to-clean surface even in dusty environments
  • False alarms minimized by continuous monitoring of detector pollution
  • Easy to replace and service
  • C-TEC Heat/Smoke Detector
  • Carries the prestigious ‘CertAlarm’ System 5 mark
  • Outstanding detection performance and durability
  • Wide 6-33V DC operating voltage
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering unrivalled 360º visibility
  • IP42 rated
  • Suitable for use with virtually all known conventional fire panels & many 12V security systems
  • Low current draw - just 30µA quiescent at 24V
  • Sophisticated onboard detection algorithms help reduce false alarms by rejecting momentary abnormal readings
  • Simple ‘click and twist’ design and easy-fit base reduces installation time and inspection costs
  • FP 1-14 Zone C-TEC Fire Panel
  • Robust metal lid and metal back box
  • True three wire operation of sounder and detector circuits (Ov is common) for considerable cost savings on installation
  • Separate indicators for open and short circuit fault, sounder fault and battery/power supply fault
  • Non-latching ‘class change’ sounder input, latching fire and non-latching fault outputs (available via optional expansion loom)
  • Fault buzzer mute facility
  • Short circuit = fire facility (pre-1980 BS, no resistors in call points), selectable on a zone by zone basis for retro-installations
  • One man walk test and zone isolate facility
  • Ancillary connections for repeater panels and other system add- including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc )